Features
The Philips Respironics Esprit is a ventilator that offers both non-invasive and invasive means of ventilation for patients. The Ventilator can proved continuous ad intermittent ventilation for patients ranging from neonates, pediatrics, and adults. The Respironics Esprit is a microprocessor powered ventilation machine that offers a range of modes and breathing types, including; volume control, and pressure control. The system has no air compressor in the machine making it easy to run off of either Ac power or by a battery pack or external battery. At the same time, Esprit has incorporated a fast, high-performance blower to remove the need for any air source gas. The Philips Respironics ventilation system has a full-color touch screen display making it easy to use.
- Pressure Support, Pressure Control Ventilation.
- Fully integrated microprocessor control for system control and monitoring.
- 100 cm H2O pressure capability and 200 liter per minute flow.
- Risetime Control, on-board Auto-PEEP measurement and breath-by-breath oxygen mixing.
- Pressure Control and Noninvasion Ventilation Settings.
- Alarm and Status Indicators.
- Pressure Bargraph/Breath Indicator.
- On-board Systems Self-diagnostics.
- Can be operated by AC power, a battery pack, or an external battery.
- Invasive and noninvasive modes.
- Compressor-based ventilator.
- Infrared touchscreen.
Breath Types
- Volume Controlled Ventilation: VCV
- Pressure Controlled Ventilation: PCV
- Non-Invasive Positive Pressure Ventilation: NPPV
- Apnea Ventilation
Modes
- Assist/Control (A/C): VCV, PCV
- SIMV: VCV, PCV
- CPAP: VCV, PCV
- Spont/T: NPPV
- Spont: NPPV
Volume Control
- Respiratory Rate: 1 to 80 bpm
- Tidal Volume: 50 to 2500 ml
- Peak Inhalation Flow: 3 to 140 lpm (compliance compensated, actual to 200 lpm)
- PEEP: 0 to 35 cmH2O
- PSV Pressure: 0 to 35 cmH2O
- Inhalation Trigger: Pressure Sensitivity: -20 to -0.1 cmH2O (hPA) (Resolution is 0.1 cmH2O (hPa); Flow Sensitivity: 0.5 to 20 lpm (Resolution is 0.1 lpm)
- Exhalation Trigger: 10 to 45% of inspiratory peak flow
- Rise Time: 0.1 to 0.9 seconds (Resolution is 0.1 second)
- %O2: 21% to 100%
- Insp. Hold: 0 to 2.0 seconds (Resolution is 0.1 second)
- Flow Waveform: Descending ramp, square
- Patient Type: Adult/Pediatric
- Apnea Rate: 1-80 bpm
Pressure Controls
- Respiratory Rate: 1 to 80 bpm
- PCV Pressure: 5 to 100 cmH2O (hPa) Relative to PEEP)
- Inhalation Time: 0.1 to 9.9 seconds (Resolution is 1 second)
- PEEP: 0 to 35 cmH2O
- PSV Pressure: 0 to 100 cmH2O (Relative to PEEP) is 0.1 cmH2O (hPa); Flow Sensitivity: 0.5 to 20 lpm (Resolution is 0.1 lpm)
- Exhalation Trigger: 10 to 45% of inspiratory peak flow
- Rise Time: 0.1 to 0.9 seconds (Resolution is 0.1 second)
- %O2: 21% to 100%
- Patient Type: Adult/Pediatric
- Apnea Rate: 1-80 bpm
Non-Invasive Controls
- Respiratory Rate: 1 to 80 bpm
- EPAP: 2 to 25 cmH2O (hPa)
- IPAP: 2 to 25 cmH2O (hPa)
- Inhalation Time: 0.1 to 9.9 seconds (Resolution is 0.1 second)
- Rise Time: 0.1 to 9.9 seconds (Resolution is 0.1 second)
- Inhalation Trigger: Flow Sensitivity: 0.5 to 20 lpm from base flow of 3 lpm above sensitivity (Resolution is 0.1 lpm)
- Exhalation Trigger: 10 to 45% of inspiratory peak flow
- %O2: 21% to 100%
- Patient Type: Adult/Pediatric
- Apnea Rate: 1-80 bpm
Refurbished Philips Respironics Espirit V1000 Ventilator
Easy Return And Exchange Policy
Non Returnable
Installation
Free
Product Condition
Refurbished
Brand
Philips Respironics
Warranty Policy :
6 Month's
Delivery Time :
15 To 25 Day's