DESCRIPTION
Clinicians Need To Respond Swiftly To Rapid Changes In Their Patient's Condition. Having A Highly Reliable, Versatile Patient Monitoring Solution On Hand Saves Precious Time In Determining The Best Course Of Care. G40e Is Your Choice For A Cost-Effective, Easy To Learn, Pre-Configured Bedside Monitor That Provides Reliable Measurements (Philips ST/AR ECG and FAST-SpO₂).
FEATURES
ADVANCED FUNCTIONALITIES
To Accommodate Different Clinical Environments, The G40e Delivers Real-Time Data About Cardiac And Respiratory Conditions. In Addition To Basic Monitoring Parameters, Such As Philips St/Ar 3- And 5-Lead Ecg/ Respiration, Nbp, 2 Temperatures, And Philips Spo₂/Pr, St And Arrhythmia Monitoring, It Also Provides 2-Channel Invasive Blood Pressure And Microstream Etco₂ Monitoring As Options.
EASE OF USE
The Monitor Has A 12.1” Display With Flexible Display Modes, Such As Big Number Display, Minitrend, Oxycrg, As Well As Auto Waveform Channel Height Adjustment Function To Fit Various Clinical Settings. Intuitive Menus, Fixed Key Access, Bright Color Screen And Optional Touchscreen Were All Designed For Maximum Ease Of Use.
NETWORKING AND DATA MANAGEMENT
The G40e Comes Standard With Lan Networking Capabilities For Facilities Looking To Create A Network With A Bi-Directional Communication With Philips Efficia CMS200 Central Monitoring System Or Require Data Output In HL7 Format.
COMPACT AND COST-EFFECTIVE
Built According To Philips Exacting Quality Standards, The G40e Patient Monitor Offers Market-Proven Essential Parameters In A Compact, Cost-Effective Monitor To Provide Accurate Measurement Results Upon Your Tight Budget. The Alarm Latch Function Helps Reduce Alarm Fatigue To Form A Silent Care Environment.
WORKS WITH EFFICIA CONSUMABLES
The G40e Patient Monitor Is Designed To Be Compatible With Philips Efficia Consumables, Which Are Also Used On Philips Efficia Cm Series Patient Monitors, To Lower Your Total Cost Of Ownership By Sharing Philips Consumables Across Different Care Settings.
INVASIVE BLOOD PRESSURE ACCURACY
±4 mmHg (0.53 kPa) Or ±4 % Of Reading, Whichever Is Greater
DISPLAY
Type : Color TFT LCD, 4:3
Size : 10.4+611:631"
Resolution : 800 x 600 Pixels
Channels : Max 11 Channels (Auto Waveform Channel Height Adjustment)
POWER SUPPLY
AC Power Input : 100 - 240 VAC, 50/60 Hz
Battery : Rechargeable Li-Ion Battery Maximum 2.5 Hour Continuous Monitoring (1 Battery
WEIGHT AND DIMENSION
Net Weight : Approx. 3.5 kg Without Battery
Dimensions (W x D x H) : 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.)
DATA REVIEW AND STORAGE
Data Review And Storage : 1600- NBP Data, 1200 Hr Trend Graph, 120 Min Full Disclosure ECG 1, 200 - Alarm & Arrhythmia Events
EXTERNAL INTERFACE (STANDARD)
External Interface : ECG Analog Output VGA Output Nurse Call LAN USB
Phillis G40E Multipara Monitor
Easy Return And Exchange Policy
Non Returnable
Installation
No Required
Product Condition
New
Brand
Phillips
Warranty Policy :
One Year
Delivery Time :
10 To 15 Day's
CAPNOGRAPHY (ETCO2, OPTIONAL)
Method
Microstream, Infrared Absorption (Oridion)
Parameters
awRR, etCO₂, inCO₂
Measurement Range
0 - 99 mmHg (0 kPa - 13.2 kPa)
Accuracy+C781, 0 – 38 Mmhg (0 Kpa – 5.1 Kpa)
±2 mmHg (±0.28 kPa)
Accuracy, 39 Mmhg – 99 Mmhg (5.2 Kpa – 13.2 Kpa)
± (5% Of Reading + 0.08% For Every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa)
Awrr Range
0-150 rpm
Awrr Accuracy, 3 Rpm – 70 Rpm
±1 rpm
Awrr Accuracy, 71 Rpm – 120 Rpm
±2 rpm
Awrr Accuracy, 121 Rpm – 150 Rpm
±3 rpm
INVASIVE BLOOD PRESSURE (IBP, 2- CHANNEL, OPTIONAL
Parameters
SYS/DIA/MAP/Pulse Rate
Measurement Range
-50 - 400 mmHg (-6.6 kPa - 53.3 kPa)
Waveform Speed
6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Resolution
1 mmHg (0.13 kPa)
Units
mmHg/kPa/cmH₂O
Transducer Sensitivity
5 uV/V/mmHg
Pulse Rate Range
30 bpm – 254 bpm
Pulse Rate Accuracy
±2 bpm or ±2%, Whichever Is Greater
Sampling Rate
62.5 Samples Per Second
RECORDER (OPTIONAL)
Type
Built-In Thermal Recorder, 3 Channels
Print Mode
Real-Time Recording, Timed Recording, Alarm-Activated Recording
Print Speed
Auto, 12.5 mm/s, 25 mm/s, 50 mm/s
CARDIAC OUTPUT (OPTIONAL)
Measurement Method
Right Heart Thermodilution
Measurement Range
0.1 L/Min - 20.0 L/Min
Measurement Accuracy
±0.2 L/Min Or ±10 %, Whichever Is Greater
Blood Temperature Range
27℃ - 43℃ (80.6℉ - 109.4℉)
Blood Temperature Accuracy
± 0.1℃
Injection Temperature
0℃ - 27℃ (32℉ - 80.6℉)