Nidek has built up a reputation of providing reliable medical technology solutions to support modern and effective healthcare at all leves. Nidek combines exprience and expertise, relevant technologies, and continuous testing so that all instruments deliver proven performanceeven in challenging situations.
Product Features
- For Adult, Pediatrics and neonates
- 12.1 inch colour TFT LCD display with high resolution
- Automatic freezing and ST segment analysis function
- 96 hours trend chart and alarm function
- 100 groups of VPC data of HR, Temp, Spo2 and RR of patient are stored when VPC occurs
- Storing 400 groups’ data of HR, Temp, Spo2 and RR of patient are stored when NIBP measured
- Can be used with ESU (Electro surgical unit), defibrillator and pacemaker simultaneously
The HORIZON is a 12.1 inch five parameter monitor. It can measure: SpO2 & Pulse Rate, NIBP, ECG, Temperature, Respiration. The unit comes with optional printer and in-built battery back-up. It has a high resolution TFT display for easy viewing.
NIDEK Horizon ECO Five para monitor (12.1 Inch Display)
Easy Return And Exchange Policy
Non Returnable
Installation
No Required
Product Condition
New
Brand
Phillips
Warranty Policy :
One Year
Delivery Time :
8 To 15 Day's
ECG
Lead Type
3-Lead Or 5-Lead Selectable
Lead Selection, 3-Lead
I, II, III
Lead Selection, 5-Lead
I, II, III, aVR aVL, aVF. V
Hr Measurement
Adult/Pediatric: 15 bpm-300 bpm Neonatal 15 bpm - 300 bpm Step 1 bpm
Hr Accuracy
15 bpm or ±1%, Whichever is
Arrhythmia
21 calls
St Measurement Range
-25 mV-+2 5 mV
Waveform Speed
6.25 mm/s 12.5 mm/s, 25 mm/s,
Gain Selection
x 1/4, x 1/2 x 1, x2, x 4, Auto
Pacemaker Detection
Yes
NON-INVASIVE BLOOD PRESSURE (NIBP)
Method
Automatic Oscillometic
Parameters
SYS/DIA/MAP/Pulse Rate
Operating Mode
Manual/Auto/STAT
Auto Measure Intervals
3, 5, 10, 15, 30, 60, 90, 120, 240 480 Minutes
Units
mmHg/kPa
Cuff Pressure Range , Adult/ Pediatric
0-300 mmHg (0 kPa -40.0 kPa)
Cuff Pressure Range , Neonatal
0-150 mmHg (0 kPa - 20.0 kPa)
Systolic Measurement Range, Adult /Pediatric
Systolic Measurement 30mm rig-135 mmHg (4 0 kPa -33.9 kPa)
Systolic Measurement Range, Neonatal
30 mmHg -135 mmHg (4.0kPa-18.0 kPa)
Diastolic Measurement Range , Adult / Pediatric
10 mmHg -220 mmHg (1.3 kPa-29.3 kPa)
Diastolic Measurement Range , Neonatal
10 mmHg -110 mmHg (1.3 kPa-14.7 kPa)
Map Measurement Range , Adult / Pediatric
20 mmHg -235 mmHg (2.7 kPa-31.3 kPa)
MAP Measurement Range ,Neonatal
20 mmHg -125 mmHg (2.7 kPa-16.7 kPa)
Accuracy , Maximum standard Deviation
8 mmHg (1.1 kPa)
Accuracy , Mean Error
土5 mmHg (土0.7 kPa)
Pulse rate Range
40 bpm -240 bpm
Pulse Rate Accuracy
土 5 bpm or 土5%, Whichever is Greater