Edan F3 Fetal Monitor is amazingly lightweight and portable, which makes it suitable for outpatient service. With the latest technologies from EDAN, F3 offers an extensive set of monitoring parameters such as FHR, TOCO, DECG, IUP and fetal movement.

Fetaures:

  • Foldable color screen
  •  Backup memory for seamless monitoring
  •  Built-in long life thermal printer
  •  Compatible with 150/152 mm thermal recording paper
  •  Large numeric and graphic display for ease of readability
  •  FHR signal quality indicator
  •  Signals Overlap Verification to separate twins FHR
  •  Fast printing of stored traces
  •  Long life Li-ion battery guarantees the mobility of F3
  •  PC management software and central monitoring system supportive
  •  Convenient probe rack and compact design
  •  USB port enables memory expansion
  •  DECG & IUP parameters optional

EDAN F3 Fetal monitor

₹105,000.00 Regular Price
₹103,040.00Sale Price
Taxes Included |
  • Easy Return And Exchange Policy

    Non Returnable 

  • Installation

    No Required 

  • Product Condition

    New 

  • Brand

    EDAN

  • Warranty Policy :

    One Year

  • Delivery Time :

    8 To 15 Day's 

  • ECG

    Lead Type

    3-Lead Or 5-Lead Selectable

    Lead Selection, 3-Lead

    I, II, III

    Lead Selection, 5-Lead

    I, II, III, aVR aVL, aVF. V

    Hr Measurement

    Adult/Pediatric: 15 bpm-300 bpm Neonatal 15 bpm - 300 bpm Step 1 bpm

    Hr Accuracy

    15 bpm or ±1%, Whichever is

    Arrhythmia

    21 calls

    St Measurement Range 

    -25 mV-+2 5 mV

    Waveform Speed

    6.25 mm/s 12.5 mm/s, 25 mm/s,

    Gain Selection

    x 1/4, x 1/2 x 1, x2, x 4, Auto

    Pacemaker Detection

    Yes

  • NON-INVASIVE BLOOD PRESSURE (NIBP)

    Method

    Automatic Oscillometic 

    Parameters

    SYS/DIA/MAP/Pulse Rate

    Operating Mode

    Manual/Auto/STAT

    Auto Measure Intervals 

    3, 5, 10, 15, 30, 60, 90, 120, 240 480 Minutes

    Units

    mmHg/kPa

    Cuff Pressure Range , Adult/ Pediatric 

    0-300 mmHg (0 kPa -40.0 kPa)

    Cuff Pressure Range , Neonatal

    0-150 mmHg (0 kPa - 20.0 kPa)

    Systolic Measurement Range, Adult /Pediatric 

    Systolic Measurement 30mm rig-135 mmHg (4 0 kPa -33.9 kPa)

    Systolic Measurement Range, Neonatal

    30 mmHg -135 mmHg (4.0kPa-18.0 kPa)

    Diastolic Measurement Range , Adult / Pediatric 

    10 mmHg -220 mmHg (1.3 kPa-29.3 kPa)

    Diastolic Measurement Range , Neonatal 

    10 mmHg -110 mmHg (1.3 kPa-14.7  kPa)

    Map Measurement Range , Adult / Pediatric 

    20 mmHg -235 mmHg (2.7  kPa-31.3 kPa)

    MAP Measurement Range ,Neonatal 

    20 mmHg -125 mmHg (2.7 kPa-16.7 kPa)

    Accuracy , Maximum standard Deviation 

    8 mmHg (1.1 kPa)

    Accuracy , Mean Error 

    土5 mmHg (土0.7 kPa)

    Pulse rate Range

    40 bpm -240 bpm

    Pulse Rate Accuracy

    土 5 bpm or 土5%, Whichever is Greater