top of page
  • Front loading with manual plunger opening syringe pump.
  • Fully Micro Processor Controlled Based System • Automatic Syringe size detection' of 5,10,20,50/60 ml.
  • Portable, Durable, Light Weight, use friendly and easy to operate
  • 3.2" Large Graphics display indicates Rate (in big font) Infused Volume, Time Remain, Drug Name, Set Volume, Syringe size, Syringe Name.
  • Display show continuously occlusion pressure graphically • Any brand of Syringe can be calibrated and use
  • User can set bolus program as per patient requirement online or programmable.
  • Last program continue facility
  • High volumetric accuracy over the entire delivery range
  • Anti Bolus function active when occlusion detected. It is helps to release pressure in patient vain.
  • Wide range of adjustable flow rates from 0.1 ml to 1500ml per hour
  •  Compatible with syringe range of 5ml, 10ml, 20/30ml and 50/60ml
  •  Stand by mode facility available
  •  Ideally suitable for ICU, ICCU, NICU, PICU, OT, Pain Management Treatment.
  •  Visual alarm from all four side.
  • Stackable Syringe Pump.

SPECIFICATIONS

  • Overall Accuracy : +/2% (Measured Time >1 Hr; Min ,0.2ml)

  • Flow Rate Range :  0.1-50ml/Hr For 10 Ml Syringe                                                0.1-100ml/Hr For 20 Ml Syringe                                                  0.1-120ml/Hr For 30 Ml  Syringe                                                 0.1-1500ml/Hr For 50/60 Ml Syringe(Above 200.1 With Password Protected In  High Infusion 

  • Infusion Volume Limit :  60ml, Programmable Every 0.1ml

  • Bolus Rate :     100ml/Hr, 200ml/Hr, 500ml/Hr And 1200ml/ Hr                                       (Depends On  Syringe Size)

  • Occlusion Detection : Programmable Three Level

  • Pressure Limit :               Low 0.4+/0.08 Bar                                                                   Medium 0.8+/0.20 Bar                                                                  High 1.2+/0.25 Bar

  • Kvo Rate :  1% Of Selected Infusion Rate   But Min 0.1ml/Hr

  • Syringe Type Used : Bi Braun-Omnifix, Bi Braun-Perfuser, Bd-Presise, Bd- Discardit, Dispovan, Romson,Nirlife & Brand Of 5,10,20,30,50,60 Ml syringes With Their Different Models.

  • Drug Library :   50 Numbers Of Different  Drugs

  • Indicators :  Alarms, Run And Mains                                 

  • Alarms : Battery, Low Battery,Occlusion, No Syringe, 5 Minute Pre Alarm, End Of   Infusion, Anti Bolus-Kvo  Active, Wrong Syringe Loaded

POWER

  • Power Supply Internal : Ac Input Range 110v To 280 Volt Ac, 50/60hz

  • Battery :  Inbuilt Smf Nimh (Shield Maintenance Free)

  • Battery Back Up On :  10 To 12 Hrs. Under  Standard Condition.

  • Operating Range                          

  • Power Consumption :                    10 Watts Max.

HOUSING AND CONSTRUCTION

  • Weight :        2.0 Kg Approx.

  • Dimension :   290 Mm (L),195 Mm (H).165 Mm (W) Approx