SHORT SPECIFICATION
- Up To 200ecg Storage
- Manual
- Auto And Arrhythmia Analysis Mode
- Touch screen TFT Display
- Battery Backup- 2-3 hrs.
FEATURES
Recording And Displaying Ecg Waveform In Auto/Manual Mode Measuring And Diagnosing Ecg Waveform Parameters Automatically Prompting For “Leadoff” And “Lack Of Paper
Sync Collection For 12-Lead Ecg, Adopt Digital Signal Processing Technology And Get High-Quality Ecg Waveform Via Power Frequency Filter, Baseline Filter And Emg Filter Of Ecg Signal.
Display Of 3/6/12-Lead Ecg, Print Mode, Sensitivity, Paper Speed And Filter State, Etc. On One Screen, Convenient For Contrastively Diagnosing.
Multiple Printing Modes And Formats, Including Auto 12x1, Auto 6x2+1, Auto 6x2+1_h, Auto 6x2, Auto 6x2_h, Auto 3x4+1, Auto 3x4+2, Rhythm 12, Rhythm 10, Rhythm 8, Rhythm 6, Manual, Etc. Trend Chart And Histogram Of P-R Interval Can Be Printed, Waveform Length Printed Can Be Adjusted, And With Time Print Function, Which Meets Different Requirements.
Paper Speed: 5mm/S, 6.25mm/S, 10mm/S, 12.5mm/S, 25mm/S, 50mm/S.
With The Functions Of Auto-Analysis And Auto-Diagnosis For Routine Ecg Parameters, Provide Measurement Results And Auto-Diagnosis Conclusion For Hr, P-R Interval, P Duration, Qrs Duration, T Duration, Q-T Interval, Q-Tc, P Axis, Qrs Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), Etc. Which Reduces The Doctor's Burden.
Built-In Memory Stores Up To 1000 Cases, Convenient For Case Review And Statistics.
Multi-Language(Turkish, French, Chinese, English, German, Kazakhstan, Polish, Portuguese, Russian, Slovenian, Spanish And Ukrainian) Interface And Report.
In Optimal Dc State, Up To 10-Hour Standby Time, Continuous Print More Than 3-Hour, Record Up To 300 Ecg Waveform(Commonly, It Is 3s Case), Which Meets The Requirements Of Visiting A Patient At Home And Body Examination.
STANDARD
A Lead Cable
A Limb Electrode
A Chest Electrode
A Thermal Recording Paper
A Power Cord
An Earth Wire
A User Manual
OPTIONAL
ECG-Sync Software + USB Cable
ECG Electrode
Conductive Paste
USB Cable
Remote Operation Guide
CONTEC - 12 channel ECG machine
Easy Return And Exchange Policy
Non Returnable
Installation
No Required
Product Condition
New
Brand
Contec
Warranty Policy :
One Year
Delivery Time :
8 To 12 Day's
Technical Specification
Screen Size
8 Inches
Leads
12 Leads
Input Way
Floating And Defibrillation Protection
Lead
Standard 12 Leads(Model:Bip0057)
Patient Leak Current
<10µa
Input Impedance
≥50mω
Frequency Response
0.05hz~150 Hz(-3db)
Time Constant
Time Constant>3.2s
Cmrr
>60db, >100db( Adding Filter)
Emg Interference Filter
35hz(-3db)
Recording Way
Thermal Printing System
Specification Of Recording Paper
210mm(W)*20m(L) High-Speed Thermal Paper
Paper Speed
Auto Record: 25mm/S, 50mm/S, Error:±5%
Rhythm Record: 25mm/S, 50mm/S, Error:±5%
Manual Record:5mm/S, 6.25mm/S, 10mm/S, 12.5mm/S, 25mm/S, 50mm/S, Error:±5%
Sensitivity Selections
2.5,5,10,20,40mm/Mv, Error:±5%. Standard Sensitivity Is 10mm/Mv±0.2mm/Mv.
Auto Record
Record Setup According To Auto-Record Format And Mode, Automatically Changing Leads, Measuring And Analyzing.
Rhythm Record
Record Setup According To Rhythm Record Format And Mode, Automatically Measuring And Analyzing.
Manual Record
Record Setup According To Manual Record Format, Manually Changing Leads.
Measurement Parameters
Hr, P-R Interval, P Duration, Qrs Duration, T Duration, Q-T Interval, Q-Tc, P A*Is, Qrs A*Is, T A*Is, R(V5) , S(V1) , R(V5)+S(V1)
Product Safety Type
Class I Cf Applied Part; There Is Defibrillation And Pacing Protection Circuit In It.
Enduring Polarization Voltage
±300mv
Noise Level
≤15µvp-P
Fuse Specification
2 Pcs Φ5*20mm Ac Time Lag; T1.6a/250v(Power Supply 220v)
Size
340mm(L)*320mm(W)*85mm(H)
Warranty
1 Year
Net Weight
3.2kg