SHORT SPECIFICATION
- Volume Mode
- Time Mode
- Bolus
- Auto Detect syringe
- Easy Operate
- Alarm System
- Battery Backup- 3-4 hrs
FEATURES
- Hd Lcd Display, High Capacity Words, Friendly User Interface, Dynamically Display Working Status; 
- Audible And Visual Alarm For Occlusion, Empty, Near Empty, Low Battery, End Of Infusion, Syringe Loose, Wrong Setting, Etc.; 
- Compatible With 5ml, 10ml, 20ml, 30ml, 50/60ml Syringe Of Any Brands; 
- Preset Solution Volume To Greatly Reduce The Workload Of Nurses; 
- Three Working Modes: Rate Mode, Time Volume Mode, Dosage Weight Mode; 
- Three Levels Of Occlusion: High, Medium And Low; 
- Purge And Bolus Function; 
- Kvo (Keep-Vein-Open) Automatically Opens As Injection Is Completed, Kvo Rate Is 0.1-5ml/H(0.1ml/H Step); 
- Freely Stackable: Freely Stack One Syringe Pump Onto Another To Provide Multiple Solutions, Which Have A Wide Range Of Clinical Applications; 
- Power Source: Ac100---240v, 50/60hz; Internal Battery, Dc12v Car Charge; 
- One-Key Operation Makes Setup Easy And Simple; 
- Syringe Plunger Grabble Detector, Operable With One Hand In A No-Germ Environment; 
- Automatically Record The Settings Of Last Injection 
EASY OPERATION
Brand New Appearance Provide Better Experience ;Clearly Lcd And Digital Tube Dual Display ;Simple Rate Mode With One Key Start, Easy To Operate
PRECISION MORE SAFER
- Three Occlusion Level For Option 
- Intelligent Recognition Of The 10ml、20ml、30ml、50ml(60ml) Syringe, Can Work With Any Brand Syringe After Calibration 
INTELLIGENT & SAFE
- Low Noise And Less Vibration Are Supported By Application Of Motor Driver Ic Imported From German And Motor Imported From Japan. 
- Unique Voice, Word And Light Combination Alarms, Very Faster And Reliable 
- Can Be Stackable To Save Space 
BYOND Syringe Pump
- Easy Return And Exchange Policy- Non Returnable 
- Installation- No Required 
- Product Condition- New 
- Brand- Byond 
- Warranty Policy :- One Year 
- Delivery Time :- 8 To 12 Day's 
- TECHNICAL SPECIFICATION- Unique Human Voice Alarm System - The Device Triggers The Human Voice Prompt And Stops Injection Automatically When There Is Any Malfunction, Making The Infusion Process Safer And More Reliable. - Rate: - 50/60ml Syringe: 0.1ml/h ~ 999.9ml/h (0.1ml/h step) 1,000ml/h ~ 1,500ml/h (1ml/h step) 30ml Syringe: 0.1ml/h ~ 900.0ml/h (0.1ml/h step) 20ml Syringe: 0.1ml/h ~ 600.0ml/h (0.1ml/h step) 10ml Syringe: 0.1ml/h ~ 300.0ml/h (0.1ml/h step) - Flow Rate Accuracy - Within ±3% (after correct calibration) - Mechanical precision - Within ± 2% - Bolus Rate - 50/60ml Syringe: 1,200ml/h 30 ml Syringe: 720ml/h 20 ml Syringe: 480ml/h 10 ml Syringe: 240ml/h - Purge Rate - 50/60ml Syringe: 1,500ml/h 30ml Syringe: 900ml/h 20ml Syringe: 600ml/h 10ml Syringe: 300ml/h - Volume Limit - 0.1ml ~ 9999.9ml (0.1ml step) - Total Injection Volume - 0.1ml ~ 9999.9ml (0.1ml step) - Occlusion of Single Channel Syringe Pump - High: 800mmHg ± 200mmHg (106.7kPa ± 26.7kPa) Medium: 50/600mmHg ± 100mmHg (66.7kPa ±13.3kPa) Low: 300mmHg ±100mmHg (40.7kPa ±13.3kPa ) - Alarms - Injection Soon Finishes, End Of Injection,Occlusion, Improper Installation Of Syringe, Wrong Setting, Low Battery, Syringe Loose Etc. - Power Source - AC 100V ~ 240V, 50/60Hz; Internal Rechargeable Li Battery, Capacity & Ge;1,600mah, 4 Hours Internal Battery Backup - KVO rate - 1ml/h - Fuse - F1AL/250/60V, 2pcs inside - Power Consumption - 30VA - IP Classification - IPX4 - Equipment Classification - Class II, Internal Power Supply, Type CF - Operating Condition - Ambient Temperature: +5℃~ +40℃ - Relative Humidity - 20 ~ 90% - Transport & Storage Condition - Ambient Temperature:-30℃~ +55℃ - Relative Humidity - ≤95% - Dimension - 280mm (L) & Times;210mm(W) & Times;130mm(H) - Weight - 2.2kg (Net Weight) 