DESCRIPTION
Reliable Patient Monitor For Ot And Critical Care Environments, Vivid Vue 12 Comes With A 12.1" High Resolution Display With An Optional Touchscreen Feature And Allows Monitoring Advanced Parameters Such As IBP, CO2, Gas Monitoring. It Has Integrated Hl7 Communication Protocol With Its Connectivity.
Vivid Vue 10/12 Vivid Vue Is The Latest Addition In BPL Portfolio Of Patient Monitoring, Vivid Vue Designed To Provide Highest Quality Of Patient Care Without Compromise.
Vivid Vue Provides Comprehensive Parameter Monitoring, A Full Featured System Has Oxycrg Specially For Neonatal Monitoring, Trend Data With Full Disclosure Of All Leads Of ECG & Viewing Of Stored Alarm Events With Relevant Parameter Values And Waveforms. Also Has 12-Lead ECG Capability (Optional) With Arrhythmia Detection And St Segment Analysis That Ensure A High Standard Of Monitoring Across All Care Areas.
Vivid Vue Is Designed To Integrate With The Hospital Information System (Hl7 Protocol), Central Nursing Station, Nurse Call System, Slave Display And Has A Defibrillator Synchronization Output Connector. Trend Data & Screen Shot Can Be Transferred To USB.
FEATURES
12.1" High-Resolution Display (Optional Touchscreen)
Standard Configuration - ECG, RESP, SPO2 (Masimo / Nellcor / BPL Oxysat+), NIBP (Suntech), TEMP (Optional 12-Lead ECG)
Optional Parameters - Dual IBP, ETCO2 (Masimo Sensors), Anesthesia Gas Monitoring (Masimo Sensors)
Enhanced Connectivity - Hl7 With His Connectivity, USB For Patient Data Output, Dvi For External (Slave) Display, Nurse Call Function. Optional: Medius+ Central Nursing Station With Remote Monitoring Feature
Convenient Feature Of Standby, Night Mode & Snapshot (Screenshot)
Comprehensive Data Storage Available
High Performance Li-Ion Battery, Providing Up To 3.5 Hrs Backup Time In Low Power Consumption
2 CHANNEL OF IBP MONITORING (INVASIVE BLOOD PRESSURE)
CO2 MONITORING (MASIMO)
SIDESTREAM ETCO2 ANALYZER
MODEL: ISA CO2
Measures: ETCO2, FICO2, RR.
Measurement Range: 0.0 – 25.0 Vol% (0 mmHg~190 mmHg).
Accuracy: 0~15%: ±(0.2 Vol% + 2% Of Reading); 15~25%: Not Defined.
Display Unit: Vol% Or MmHg.
Respiration Rate (Awrr): 0 To 150 ± 1 Breaths/Min.
Warm-Up Time: < 10 Seconds.
Calibration: An Automatic Zeroing Is Performed 1 To 3 Times Per Day.
Dimensions With Weight: 1.3” X 3.1” X 1.9”; <130 G
MAINSTREAM ETCO2 ANALYZER
MODEL: IRMA CO2
Measures: ETCO2, FICO2, Rr.
Measurement Range: 0.0 – 25.0 Vol% (0 mmHg~190 mmHg).
Accuracy: 0~15%: ±(0.2 Vol% + 2% Of Reading); 15~25%: Not Defined.
Display Unit: Vol% Or MmHg.
Respiration Rate (Awrr): 0 To 150 ± 1 Breaths/Min. Warm-Up Time: < 10 Seconds.
Calibration: Zeroing Recommended When Changing Airway Adapter.
Dimensions With Weight: 1.49” X 1.45” X 1.34”; < 25 G
E MULTI GAS MONITORING (MASIMO)
SIDESTREAM GAS ANALYZER
MODEL: ISA OR+ (WITH O2)
Measures: EtCO2, RR, N2O, O2, Agent Identification.
Dimensions With Weight: 1.9” x 3.5” x 3.9”; <420 g
SIDESTREAM GAS ANALYZER
MODEL: ISA AX+ (WITHOUT O2)
Measures: ETCO2, RR, N2O, Agent Identification.
Dimensions With Weight: 1.3” x 3.1” x 1.9”; <130 g
MAINSTREAM GAS ANALYZER (AVAILABLE ONLY WITHOUT O2)
MODEL: IRMA AX+
Measures: EtCO2, RR, N2O, Agent Identification.
Dimensions With Weight: 1.49” x 1.45” x 1.34”; < 25 g
BPL VIVID VUE 12'' Multipara Patient Monitor
Easy Return And Exchange Policy
Non Returnable
Installation
No Required
Product Condition
New
Brand
BPL
Warranty Policy :
One Year
Delivery Time :
8 To 12 Day's
GENERAL
Display
Vivid Vue 10: 10.4"(Optional Touch Screen) Vivid Vue 12: 12.1"(Optional Touch Screen)
Resolution
Pixel : 800×600 pixels
Display Information
7 Waveforms Display /12-Lead Ecg Interface
Weight
Vivid Vue 10: < 3.8kg
Vivid Vue 12: < 3.8kg
Built-In Battery
Rechargeable Lithium Ion Battery 14.8v/2600mah; ≥ 3.5 Hrs Of Backup Time
Battery Charge Time
≤ 3.5 Hours
Dimension
Vivid Vue 10: 345mm×181mm×292mm
Vivid Vue 12: 345mm×181mm×292mm
POWER SPECIFICATIONS
Input Voltage
100V-240V AC
Frequency
50Hz/60Hz
Earth Leakage Current
< 0.3 mA
Input Current
0.6A -0.3A
Standard Requirement
According To IEC 60601-1 and IEC 60601-1-2
RECORDING SPECIFICATIONS
Method Thermal
Dot Array
Number Of Waveforms
3
Recording Paper Width
50mm
Paper Length
15 m
Paper Speed
12.5 mm/s, 25 mm/s, 50 mm/s
Recording Way
Real-Time Recording, Alarm Recording
ENVIRONMENTAL SPECIFICATION
Operating Temperature
+5°C to +40°C
Operating Humidity
15% to 85% (Non-Condensing
Operating Atmospheric Pressure
700hPa to 1060hPa
Transportation And Storage Temperature
-20°C to +55°C
Transportation And Storage Humidity
10% to 93% (Non-Condensing)
Transportation And Storage Atmospheric Pressure
500hPa to 1060hPa