SHORT SPECFICATION
- 8.4" LCD Display
- Mode of Ventilation- VCV,PCV
- SIMV
- ACMV, Epeep ,BAG And Standby
- Monitoring Perameter - Tidal Volume , Minute Volume, PR, FIO2, PEEP Obtained
- Vaporizer -Isoflurane/Sevoflurane /Halothane
- Manometer Circle Absorber System
STANDARD FEATURES
Minimum Tidal Volume Of 20mL
Suitable For Adults And Pediatric Range Of Patients
Comes With An Elegantly Designed 8.4 Inches Color LCD Screen That Displays Several Parameters
Ventilator With ePEEP (Electronic PEEP)
Spirometry (Loops And Waveforms
THIS MAKES FOR AN IDEAL ANESTHESIA DELIVERY SOLUTION FOR:
Tertiary Care Multi Speciality Hospitals
OPTIMUM FOR SURGERIES AND PROCEDURES SUCH AS:
Neurosurgery
Pediatric
Orthopedic
Gynecological
Laparoscopic
Urological
Thoracic
Minimally Invasive
Pediatric
MODES OF VENTILATION
VCV Volume Control
PCV Pressure Control
SIMV
ACMV Assist Control
PHYSICAL
Construction: Tabular, Rigid Thermostat Molded With Large Drawer For Storage. Four Large Diameter Anti-Static Castor Wheels Providing Easy Mobility. Front Castors Have Brakes.
GAS INLETS
Cylinder Yokes : Gas Specific, Pin Indexed Yokes With Slinding Steel Clamping Bar For 02 And N2O As Per Model Below: 2x02, 2xn20
Pipeline Inlets: 02, N20 And Air Pipeline Inlets
PRESSURE REDUCING REGULATORS
Highly Efficient And Reliable PRESSURE Regulators (2 Stages In PRIMA) For O2 And N20.
N20 Regulators Are Activated Only If 02 Regulators Are Pressurized. N20 Regulators Cut Off On 02 Supply Failure
PRESSURE GAUGE
* Pressure Gauge Cylinder: 02 And N20: 0 To 250 Kg/Cm2
Pipeline Systems: 02/N20/Air, Diameter- Indexed
02/N20 Piping Station Block With Pressure Gauge And 5m Hose (Optional)
FLOWMETER
5 Tube Long (230 Mm)
Flowmeters Calibrated In Double Scale For Accuracy And Clarity In Reading.
3 Gas: 02, N2o, Air (PRIMA).
Anti-Hypoxia System: Minimum 25-30% O2 At About 3 kg/cm2 (PRIMA)
Scale: 02 : 0.1-1 LPM, 1-10 LPM
N20:0.1-1 LPM, 1-10 LPM
AIR: 0.1-10 LPM
N20 SAFETY CUT-OFF VALVE FOR OXYGEN SUPPLYING FAILURE
When The Pressure Of The Supplying Oxygen Drops Below About 2.5kg/Cm2. Nitrous Oxide Will Be Automatically Shut Off To Protect A Patient From The Danger Of Hypo-Oxygenation
OXYGEN FLUSH VALVE
Self-Returning Push Button
Flow: 35-75 LPM at 4 kg/cm2
ALARM FOR OXYGEN SUPPLYING FAILURE
Audio Visual Alarm With Buzzer And LED Indicator, For More Than 7 Seconds To Warn A Danger When The Pressure Of Supplying Oxygen Drops Below About 2.5kg/Cm3
VAPORIZER
Designed To Install Up To Maximum TWO Selectatec Vaporizers.
Breathing Attachment: Standard Bains Breathing Circuit
INTELLIGENT BREATHING SYSTEM
GSM Absorber With Integrated Bellows & Soda Lime Canister System Offering Highest Absorption Efficiency Offering Advance Features Like Inbuilt Apl Valve, Pressure Manometer For Breath To Breath Airway Pressure Display, Integrated O2 Sensor Offering Fio2 Monitoring, Inspiratory & Expiratory Flow Sensors Ensuring Accurate Delivery & Monitoring Of Volume .
INTEGRATED ANESTHETIC VENTILATOR
A) Vent VIII
Microprocessor Controlled Pneumatically Driven Integrated Ventilator With Ascending Bellows For Adult, Pediatric & Neonatal Application.
GENERAL
Operating Power: 100 to 240 VAC, 50/60Hz, 6.5A Battery: 12V DC, Battery backup: 2 Hrs (Full Charge Time: 4 Hrs)
DISPLAY
Screen: 8.4" Color LCD Display
DISPLAY PARAMETERS
Real Time Display Of P-T, F-T, V-T Waveforms & P-V, F-V Loops, ETCO2 (Optional),
A/C, Manual, Standby
Upto 4 Waveforms & 2 Loops Simultaneously.
Multigas Monitoring Parameters (Optional)
Digital Flow Meter (Optional)
CONTROL
Pressure, Volume And Time Controlled Ventilator
Modes: VCV, PCV, SIMV+PSV, Manual, Standby
Breath Rate: 1-100 bpm
Tidal Volume: 20-1500 ml
I: E ratio:4:1-1:10
PEEP: Integrated Electronic PEEP: 4-30 cmH2O
Flow Trigger: 1-15 L/min
Insp. Time: 0.110 sec (Increment: 0.1 sec)
Pressure Limit: (PEEP+5)-70 cmH20
Pressure Control: 5-70 cmH20
Pressure Support: 5-60 cmH20
Inspiratory Pause: 5-50%
MONITORING
Insp Tidal Volume: 0 to 1500ml
Exp Tidal Volume: 0 to 1500ml
Minute Volume: 0 to 60L
Spontaneous Minute Volume: 0 to 60L
Frequency: 0 To 100 bpm
Spontaneous Frequency: 0 To 99 bpm
I:E Ratio: 3:1 To 1:6
Peak Pressure: -12 To 100 cmH20
Mean Pressure: 0 To 100 cmH2O
Insp Plat Pressure: 0 To 100 cmH2O
Insp 02:21% To 100%
Compliance: 0 To 200mL/cmH20
Resistance: 0 To 200cmH20/(L/S)
ETCO2
ALARMS SETTINGS
Tidal Volume: 20 to 1500ml
Minute Volume: 1 to 40L
Frequency: 1 to 60 bpm
Airway Pressure: -12 to 100 cmH2O
Insp 02:21% to 100%
High Continuous Airway Pressure: Alarm When Airway Pressure Exceeds (PEEP+15) cmH20 For 15 Seconds
Negative Pressure: Alarm When Airway
Pressure Exceeds-10cmH20
Alarms For Apnea,02 Failure, Mains Failure, Low Battery.
OPTIONS
Vent X-12.1" LCD Display with VCV, PCV, SIMV,PSV, A/C, Manual + Standby Mode
OPTIONAL SYSTEMS & ACCESSORIES
TEMPERATURE COMPENSATED VAPORIZER (Optional)
It Is Possible To Use SELECTATEC Vaporizers Of Choice: Halothane / ISOFLURANE/ ENFLURANE/SEVOFLURANE Additionally Installed With A Manifold For SELECTATEC Vaporizers.
Asteros Vent Viii Workstation With Vaporizer
Easy Return And Exchange Policy
Non Returnable
Installation
Free
Product Condition
New
Brand
Medion
Warranty Policy :
One Year
Delivery Time :
20 To 25 Day's