SHORT SPECFICATION 

  • 8.4" LCD Display
  • Mode of Ventilation- VCV,PCV
  •  SIMV
  •  ACMV, Epeep ,BAG And Standby
  •  Monitoring Perameter - Tidal Volume , Minute Volume, PR, FIO2, PEEP   Obtained
  • Vaporizer -Isoflurane/Sevoflurane /Halothane
  • Manometer Circle Absorber System

 

STANDARD FEATURES

  • Minimum Tidal Volume Of 20mL

  • Suitable For Adults And Pediatric Range Of Patients

  • Comes With An Elegantly Designed 8.4 Inches Color LCD Screen That Displays Several Parameters 

  • Ventilator With ePEEP (Electronic PEEP)

  • Spirometry (Loops And Waveforms

 

THIS MAKES FOR AN IDEAL ANESTHESIA DELIVERY SOLUTION FOR:

Tertiary Care Multi Speciality Hospitals

 

OPTIMUM FOR SURGERIES AND PROCEDURES SUCH AS:

  • Neurosurgery

  • Pediatric

  • Orthopedic

  • Gynecological

  • Laparoscopic

  • Urological

  • Thoracic

  • Minimally Invasive

  • Pediatric 

 

MODES OF VENTILATION

  • VCV Volume Control

  • PCV Pressure Control

  • SIMV

  • ACMV Assist Control

 

PHYSICAL

 Construction: Tabular, Rigid Thermostat Molded With Large Drawer For Storage. Four Large Diameter Anti-Static Castor Wheels Providing Easy Mobility. Front Castors Have Brakes.

 

 GAS INLETS

  • Cylinder Yokes : Gas Specific, Pin Indexed Yokes With Slinding Steel Clamping Bar For 02 And N2O As Per Model Below:  2x02, 2xn20

  • Pipeline Inlets:  02, N20 And Air Pipeline Inlets

 

 PRESSURE REDUCING REGULATORS

  • Highly Efficient And Reliable PRESSURE Regulators (2 Stages In PRIMA) For O2 And N20.

  • N20 Regulators Are Activated Only If 02 Regulators Are Pressurized. N20 Regulators Cut Off On 02 Supply Failure

 

 PRESSURE GAUGE

  •  * Pressure Gauge Cylinder: 02 And N20: 0 To 250 Kg/Cm2

  •  Pipeline Systems: 02/N20/Air, Diameter- Indexed

  •  02/N20 Piping Station Block With Pressure Gauge And 5m Hose (Optional)

 

 FLOWMETER

  •  5 Tube Long (230 Mm)

  •  Flowmeters Calibrated In Double Scale For Accuracy And Clarity In Reading. 

  • 3 Gas: 02, N2o, Air (PRIMA). 

  • Anti-Hypoxia System: Minimum 25-30% O2 At About 3 kg/cm2 (PRIMA)

  •  Scale:     02 : 0.1-1 LPM, 1-10 LPM

              N20:0.1-1 LPM, 1-10 LPM

              AIR: 0.1-10 LPM

 

 N20 SAFETY CUT-OFF VALVE FOR OXYGEN SUPPLYING FAILURE

When The Pressure Of The Supplying Oxygen Drops Below About 2.5kg/Cm2. Nitrous Oxide Will Be Automatically Shut Off To Protect A Patient From The Danger Of Hypo-Oxygenation

 

 OXYGEN FLUSH VALVE

  •  Self-Returning Push Button

  •  Flow: 35-75 LPM at 4 kg/cm2

 

ALARM FOR OXYGEN SUPPLYING FAILURE

 Audio Visual Alarm With Buzzer And LED Indicator, For More Than 7 Seconds To Warn A Danger When The Pressure Of Supplying Oxygen Drops Below About 2.5kg/Cm3

 

 VAPORIZER

  •  Designed To Install Up To Maximum TWO Selectatec Vaporizers.

  •  Breathing Attachment: Standard Bains Breathing Circuit

 

 INTELLIGENT BREATHING SYSTEM

GSM Absorber With Integrated Bellows & Soda Lime Canister System Offering Highest Absorption Efficiency Offering Advance Features Like Inbuilt Apl Valve, Pressure Manometer For Breath To Breath Airway Pressure Display, Integrated O2 Sensor Offering Fio2 Monitoring, Inspiratory & Expiratory Flow Sensors Ensuring Accurate Delivery & Monitoring Of Volume .

 

 INTEGRATED ANESTHETIC VENTILATOR

 

 A) Vent VIII

Microprocessor Controlled Pneumatically Driven Integrated Ventilator With Ascending Bellows For Adult, Pediatric & Neonatal Application.

 

 GENERAL

 Operating Power: 100 to 240 VAC, 50/60Hz, 6.5A Battery: 12V DC, Battery backup: 2 Hrs (Full Charge Time: 4 Hrs)

 

 DISPLAY

 Screen: 8.4" Color LCD Display

 

 DISPLAY PARAMETERS

  • Real Time Display Of P-T, F-T, V-T Waveforms & P-V, F-V Loops, ETCO2 (Optional),

  • A/C, Manual, Standby 

  • Upto 4 Waveforms & 2 Loops Simultaneously.

  • Multigas Monitoring Parameters (Optional)

  • Digital Flow Meter (Optional)

 

 CONTROL

  • Pressure, Volume And Time Controlled Ventilator 

  • Modes: VCV, PCV, SIMV+PSV, Manual, Standby

  • Breath Rate: 1-100 bpm

  • Tidal Volume: 20-1500 ml

  • I: E ratio:4:1-1:10

  • PEEP: Integrated Electronic PEEP: 4-30 cmH2O

  • Flow Trigger: 1-15 L/min

  • Insp. Time: 0.110 sec (Increment: 0.1 sec)

  • Pressure Limit: (PEEP+5)-70 cmH20

  • Pressure Control: 5-70 cmH20

  • Pressure Support: 5-60 cmH20

  • Inspiratory Pause: 5-50%

 

 MONITORING

  • Insp Tidal Volume: 0 to 1500ml 

  • Exp Tidal Volume: 0 to 1500ml

  • Minute Volume: 0 to 60L

  • Spontaneous Minute Volume: 0 to 60L

  • Frequency: 0 To 100 bpm

  • Spontaneous Frequency: 0 To 99 bpm

  • I:E Ratio: 3:1 To 1:6

  • Peak Pressure: -12 To 100 cmH20

  • Mean Pressure: 0 To 100 cmH2O

  • Insp Plat Pressure: 0 To 100 cmH2O

  • Insp 02:21% To 100%

  • Compliance: 0 To 200mL/cmH20

  • Resistance: 0 To 200cmH20/(L/S)

  •  ETCO2

 

 ALARMS SETTINGS

  • Tidal Volume: 20 to 1500ml

  • Minute Volume: 1 to 40L

  • Frequency: 1 to 60 bpm 

  • Airway Pressure: -12 to 100 cmH2O

  • Insp 02:21% to 100%

  • High Continuous Airway Pressure: Alarm When Airway Pressure Exceeds (PEEP+15) cmH20 For 15 Seconds 

  • Negative Pressure: Alarm When Airway

  • Pressure Exceeds-10cmH20

  • Alarms For Apnea,02 Failure, Mains Failure, Low Battery.

 

 OPTIONS

Vent X-12.1" LCD Display with VCV, PCV, SIMV,PSV, A/C, Manual + Standby Mode

 

 OPTIONAL SYSTEMS & ACCESSORIES

TEMPERATURE COMPENSATED VAPORIZER (Optional)

 It Is Possible To Use SELECTATEC Vaporizers Of Choice: Halothane / ISOFLURANE/ ENFLURANE/SEVOFLURANE Additionally Installed With A Manifold For SELECTATEC Vaporizers.

Asteros Vent Viii Workstation With Vaporizer

₹532,000.00 Regular Price
₹504,000.00Sale Price
Taxes Included |
  • Easy Return And Exchange Policy

    Non Returnable 

  • Installation

    Free

  • Product Condition

    New 

  • Brand

    Medion 

  • Warranty Policy :

    One Year

  • Delivery Time :

    20 To 25 Day's

bottom of page