SHORT SPECIFICATION
- Pediatric To Adults
- Ulltra Quiet Turbine Technology
- 12" TFT Detachable Touch Screen
- Invasive & Non- Invasive
- Ventilation Mode -VCV(A/C) , PCV(A/C) , PRVC , SIMV(VCV)+PSV , SIMV(PCV)+PSV , SIMV(PRVC)+PSV ,SPONT/CPAP+PSV , BIVENT+PSV, NIV/CPAP , NIV-T , NIV-S/T
PRODUCT DESCRIPTION
Comprehensive ICU Ventilator Including BIVENT And PRVC
Compact, Large Capacity Battery, No Air Compressor, Intra-Hospital Mobility
Flexible Device Configuration: Equipped With A Trolley, Bed Or Ceiling Pendant Mount
Unique Metal-Based, Autoclavable, Heated Exhalation Valve
The VG70 Is A Comprehensive Transportable ICU Ventilator Including Lung Protective Ventilation Modes Such As BIVENT And PRVC. The VG70 Has Flexible Configuration Allowing For Trolley, Bed Or Ceiling Pendant Mount. As A Cost Effective Solution The VG70 Has A Metal Based Autoclavable Exhalation Valve With A Nonconsumable Design Built In Flow Sensor And Its Ventilation Software Is Upgradeable With The Available USB Port.The VG70's Optimal Ventilator Synchrony Leads To Greater Patient Comfort, The Leak Compensation System Precisely Controls The Tidal Volume Of Each Breath Delivered To The Patient By Adjusting Compensation Dosage Automatically.
The VG70 Is An Optimal Combination Of Invasive And Non-Invasive Ventilator. As Noninvasive Ventilation Is Used Increasingly In A Wide Range Of Clinical Situations, We Offer A Dual Solution. The VG70 Combines The Advantages Of A Flexible Noninvasive Ventilator With A Full-Featured Invasive Ventilator For The ICU.
Optimal Patient-Ventilator Synchronization, Increased Patient Comfort
The Unique Leak Compensation System - Keep Precise Control On The Tidal Volume Of Each Breath Delivered To The Patient By Adjusting Compensation Dosage Automatically
Advanced Trigger Technique - Enhanced Sensitivity, To Avoid Spurious Trigger Safe Ventilation Through Whole Treatment Phase Initial Treatment Phase
Noninvasive Ventilation Mode Associated With Decreased Intubation Rates, Shortened Patient Stays, Improved Patient Comfort, And A Reduced Risk Of Cross-Infection
Preset Patient’s Height And Ibw. Reduce Clinician’s Workload Stable Condition Phase
PRVC And BIVENT Employ Lung-Protective Strategies, Delivering Intelligent Ventilation
Comprehensive Lung Mechanics Monitoring Include Compliance, Airway Resistance, Peepi And Time Constant
Three Waveforms & Three Loops With User-Friendly Display Provide A Continuous Monitoring Of The Patient’s Condition Weaning Phase
Various Ventilation Modes Enhance The Weaning Process
The Unique Trigger And Leakage Compensation System Safeguard Each And Every Patient Breath Resulting In Smooth And Comfortable Breathing, Avoiding Extra Workload On The Patient And Promoting Recovery
Rsbi And Wob Provide Accurate Reference For Weaning Rehab Phase
Data Export Port Provides Connection To Hospital Monitors And Patient Data Management Systems
Provides Pressure Support For The Patient When Spontaneous Breathing Is Present
Upgradeable Ventilation System Software, With An Available USB Port
PRODUCT SPECIFICATION
Ventilation Modes : Invasive Ventilation Mode : VCV(A/C) , PCV(A/C) , PRVC , SIMV(VCV)+PSV , SIMV(PCV)+PSV SIMV(PRVC)+PSV SPONT/CPAP+PSV BIVENT+PSV Noninvasive Ventilation Mode : NIV/CPAP NIV-T , NIV-S/T
Alarm : Paw High / Low , Mve High / Low , Circuit DisconnectFIO2 High / Low , Inspiratory / Expiratory Tidal Volume Low , High Respiration Rate , Apnea , AC Failure , Nebulizer On , Low Battery , Air /O2 Supply Down , High / Low Peep , Leakage Out Of Range , Occlusion
Special Procedures : Apnea Ventilation Smart Suction Manual BreathInsp/ Exp Hold ETCO2 MeasurementNebulization Waveform Freeze
Aeonmed Brand New Ventilator
Easy Return And Exchange Policy
Non Returnable
Installation
Free
Product Condition
New
Brand
Aeonmed
Warranty Policy :
One Year
Delivery Time :
15 To 25 Day's
TECHNICAL DATA
Screen:
12〞TFT color touch screen (detachable)
Supply Gas:
O2, 0.28~0.6 MPa
Power Supply:
AC100~240 V, 50 Hz/60 Hz
Communication Interface:
RS-232 Port, Nurse call Port, Ethernet Port
Dimension (WxDxH):
322 mm x 375 mm x 366 mm (Main Unit)
547 mm x 675 mm x 950 mm (Cart)
Weight:
12.5 kg (Main Unit)
25 kg (Cart)
PARAMETERS
Tidal Volume:
20~2000 ml
Respiration Rate:
1~80 bpm
Tinsp:
0.2~9 s
Tslope:
0~2 s
Tpause:
0~4 s
I:E Ratio:
1:10~4:1
FiO2:
21%~100%
Trigger Sensitivity:
Pressure (-20~0 cmH2O, above PEEP) Flow (0.5~20 LPM)
PEEP:
0~35 cmH2O
Psupport:
0~70 cmH2O
Pinsp:
5~70 cmH2O
MONITORING
Pressure Value:
Ppeak, Pplat, Pmean, Pmin, PEEP
Volume / Flow Value:
Vti, Vte, MV, MVspont
Time Value:
Total,Fspont, I:E
Real Time Curves:
Pressure-Time, Flow-Time, Volume-Time Waveforms
Pressure-Volume, Volume-Flow, Flow-Pressure loops
Gas Monitoring:
FiO2, ETCO2
Calculated Values:
Compliance(C)
Resistance(R)
MVleak
RSBI
WOB
PEEPi